Outage Runtime

Method, assumptions and sources

The formula

1. Label average (W) = label kWh/year × 1000 ÷ 8760 hours

2. Load range (W) = label average × (real-use low … high) + other devices

3. Runtime range (h) = battery Wh × usable share (low … high) ÷ load (high … low)

Example: 600 kWh/year → 600,000 ÷ 8760 ≈ 68 W. Load range 68–103 W (100–150%). A 1,024 Wh station: 1,024 × 0.80 ÷ 103 ≈ 8.0 h up to 1,024 × 0.90 ÷ 68 ≈ 13.5 h.

Assumptions (and why)

Food-safety timing

USDA guidance (via FoodSafety.gov): a refrigerator keeps food safe for about 4 hours if unopened; a full freezer holds about 48 hours and a half-full one about 24 hours if the door stays closed. Source: FoodSafety.gov, checked 2026-11-02.

Specs

Every capacity, AC output and surge figure comes from the manufacturer's own product page, checked on the date shown on the models page. Where a maker does not state a figure, we say so instead of filling it in.

What this calculator does not do